PowaMaster



Background
#


PowaMaster is a Power System Analysis application which runs on the Microsoft Windows operating system. It caters for the modelling of balanced, meshed power system networks by representing the electrical network and equipment in an intuitive user-friendly and efficient manner.

PowaMaster is ideally suited for transmission and distribution networks, substation design and building services applications.

PowaMaster is an integrated system with all features included in all editions. There are no hidden surprises with extra modules to be purchased. All the features, such as Short Circuit (Fault Level) Calculations, Harmonic Analysis, Time Series Analysis and Protection (IDMT) Coordination work together as a coherent unit, allowing the user to perform many studies without leaving the main Graphical User Interface (GUI).

The range of functions and elements available in PowaMaster allow you to model complex networks and simulate a wide range of operating conditions.


Editions
#


There are 3 editions to choose from:

  • 🟣 PowaMaster Plus (virtually unlimited busbars),
  • 🟣 PowaMaster Basic (500 busbar limitation),
  • 🟣 PowaMaster Lite (100 busbar limitation)

PowaMaster User Interface
#



Why PowaMaster?
#


  1. Simplicity of Use - A hallmark of PowaMaster is its simplicity of use. Using a graphical interface complex networks can be simulated in an intuitive user friendly and efficient manner.
  2. Ideally suited - PowaMaster is ideally suited for transmission systems, large factories and refineries, mines and utility networks.
  3. PowaMaster is an integrated system with all features included in all editions. There are no hidden surprises with extra modules to be purchased.
  4. Data can be imported and exported - OLE links mean data can be imported and exported to a number of different utility applications giving the user flexibility and added power.
  5. Reporting capabilities - Reporting capabilities further enhance its functionality.

PowaMaster Industry Use
#


PowaMaster finds application in many of the larger industrial installations, typically:

  • Oil Refineries
  • Mines
  • Steel mills
  • Other large factories

Applications where there are multiple HV / MV networks PowaMaster is ideally suited in depicting the network on the ground:

  • Small and Large Utilities
  • Generation and Transmission Utilities

PowaMaster Main Features
#


🔷 Voltage Range
#


PowaMaster can handle any voltage modelled in a network and allows for a totally mixed system.

  • Low voltage (LV < 1000V)
  • Medium voltage (1000V MV < 44kV)
  • High voltage (HV > 44kV)
  • User defined Voltage Levels

🔷 Analysis Capabilities
#


  • Balanced 3 Phase Power Flow Calculations
  • Short Circuit Calculation (IEC 60909)
  • Protection Coordination
  • Harmonic Analysis
  • Time Series Analysis

🔹 Power Flow Analysis
#


  • Newton-Rhapson
  • Gauss-Seidel
  • Motor Starting
  • Automatic voltage limit checking and reporting
  • Automatic equipment thermal limit checking and reporting

🔹 Short Circuit Analysis (IEC 60909)
#


  • 3-phase fault
  • Phase to Ground fault
  • Phase to Phase fault
  • Double Phase to Ground fault

🔹 Time Series Analysis
#


  • Load Profile and Energy Simulations
  • Time and Date stamped load measurements
  • Load flow calculations for each measurement
  • Energy and Losses Management

🔹 Harmonic Analysis
#


  • Harmonic Source Modelling
  • Impedance Plots
  • Harmonic Distortions
  • Harmonic Current & Voltage Wave Forms

🔷 Network Modelling
#


  • Geographic network representation and modelling
  • Manual schematic network representation
  • Voltage level validations
  • Long Bus Name capability
  • Overview capability
  • Automatic feeder length calculation based on layout
  • Zooming at different levels within separate view sheets

🔹 Generator Modelling
#


  • Generator source impedance models
  • Multiple generator positions
  • Interconnected Generation

🔹 Transformer Modelling
#


  • Two winding transformers
  • Equivalent Three winding transformers
  • Auto transformers
  • Automatic tap change
  • Lock all tap change facility
  • Lock selected transformer tap change facility
  • Transformer grounding via impedance
  • Multiple transformers in parallel

🔹 Lines & Cables Modelling
#


  • Resistance, Reactance and Line Capacitance in positive & zero sequence
  • Multiple sections within a branch

🔹 Load Modelling
#


  • Constant power, current or impedance load types or combination
  • Load impedance contribution to Faults
  • General bulk load scaling functionality
  • Coincidence factor scaling functionality per load

🔹 Motor Modelling
#


  • Simple Motor steady state condition modelled as a constant power load
  • Induction Motor modelled as an equivalent circuit induction machine
  • Motor start-up calculations

🔹 Reactive Modelling
#


  • Shunt Reactance via the Shunt Capacitor Device, modelled as a constant impedance load
  • Shunt Reactance can be modelled as a Load Device with constant impedance load
  • Series Reactance via the Series Capacitor and Reactor Device, modelled as a constant impedance

🔹 Protection Modelling
#


  • IDMT relays and fuse curves with protection operating times and co-ordination studies

🔷 Other Features
#


🔹 Network Data Changes
#


  • Single Bus / Branch / Section / Transformer / Load / Generator data changing
  • Rapid Network voltage change

🔹 Reporting
#


  • User definable reports
  • Export all results to Text file or Microsoft Excel

🔷 API’s
#


PowaMaster is an OLE/COM Automation Server, exposing some of the PowaMaster functionality to applications acting as OLE/COM Automation Controllers.

Any OLE/COM enabled application can link to PowaMaster to build networks on the fly and retrieve the results.

This gives the user the ability to develop any custom functionality and use any other programming interface to link to PowaMaster, such as AutoCAD, MicroStation, GIS, Excel, C++, Visual Basic, Python, etc.