<< Click to Display Table of Contents >> Welcome to PowaMaster |
![]() ![]()
|
PowaMaster is a premier Power System Analysis tool for meshed electrical power system analysis and simulation, ideally suited for transmission and distribution systems. It focuses on balanced interconnected systems with full meshed network capability in a user friendly and efficient manner.
PowaMaster is fully integrated and not module based, which means that all the features work together as a coherent unit, allowing the user to perform many studies without leaving the main Graphical User Interface (GUI).
The range of functions and elements available in PowaMaster allow you to model complex networks and simulate a wide range of operating conditions.
The user simply draws the network using the mouse and the network elements provided. Calculations are performed when required and results are immediately displayed on the single line diagram.
Main Features
Analysis Capabilities |
oBalanced Load Flow Calculations: •Newton-Rhapson •Gauss-Seidel
oFault Level / Short Circuit Calculations (IEC 60909) •3-phase fault •phase to ground fault •phase to phase fault •double phase to ground fault
oLoad Profile and Energy simulations (Time Series Analysis) •Time and Date stamped load measurements applied to loads in the model for load flow calculations for each measurement recorded. •Energy and Losses Management
•Harmonic Source Modelling •Impedance Plots •Harmonic Distortions •Harmonic Current & Voltage Wave Forms
oTypical voltage solve ranges: LV (<400V) to HV (765kV+) •User defined Voltage Levels •Automatic voltage limit checking and reporting •Automatic equipment thermal limit checking and reporting
|
Generation / Source Modelling |
•Generation source impedance models •Multiple generation positions •Interconnected Generation
|
Transformer Modelling |
•Equivalent Three winding transformers •Auto transformers •Automatic tap change •Lock all tap change facility •Lock selected transformer tap change facility •Transformer grounding via impedance •Multiple transformers in parallel
|
Lines & Cables Modelling |
•Resistance, Reactance and Charging (Line Capacitance) in positive and zero sequence •Multiple sections within a branch
|
Load Modelling |
•Constant Power, Current or Impedance load types or combination. •Load impedance contribution to Faults. •General bulk load scaling functionality •Coincidence factor scaling functionality per load
|
Motor Modelling |
•Simple Motor modelled as a constant power load. •Induction Motor modelled as an equivalent circuit induction machine.
|
Reactive Power Modelling |
•Shunt Capacitor Device, modelled as a constant impedance load. •Shunt Reactance can be modelled as a Load Device with constant impedance load.
|
Protection Modelling |
•IDMT relays and fuse curves with protection operating times and co-ordination studies.
|
Network Modelling |
•Voltage level validation •Long Bus Name capability •Overview capability •Manual schematic network representation •Geographic network representation and modelling •Automatic feeder length calculation based on layout •Zooming at different levels within separate view sheets.
|
Network Data Changes |
•Single Bus / Branch / Section / Transformer / Load / Generator data changing •Rapid Network voltage change.
|
Reporting |
•User definable reports •Export all results to Text file or Microsoft Excel.
|
API's |
PowaMaster is an OLE/COM Automation Server, exposing some of the PowaMaster functionality to programs acting as OLE/COM Automation Controllers.
Any OLE/COM enabled application can link to PowaMaster to build networks on the fly and retrieve the results.
This gives the user the ability to develop any custom functionality and use any other programming interface to link to PowaMaster, such as AutoCAD, Microstation, GIS, Excel, C++, Visual Basic, Python, etc.
|